Battery Backup Sump Pump in Butler, PA
A 12-volt DC pump rated 2000 GPH keeps the pit empty when utility power drops. The system uses a separate float switch set six inches above the primary pump. Roto Master Pump Service wires the charger and tests the battery under load.
Roto Master Pump Service mounts the unit on the discharge line with its own check valve. The crew verifies the inverter output stays above ten amps during a simulated outage.
Call (833) 599-4825.